FAULT314.ACTION

Description

The fault F314 is triggered if a motor phase loss condition is detected. The supervision of the motor lines is started if the following preconditions are met:

  • Drive is enabled
  • Current command is injected

The parameter FAULT314.ACTION can be configured to generate a fault F314, a warning n314 or to ignore the fault event. The configuration values are:

Value Action
0 Generate Fault
1 Ignore
4 Generate warning

Restrictions: The motor phase loss condition cannot be detected if the motor is moving above a certain velocity level.

General Information

Type

NV Parameter

Units

N/A

Range

0, 1, 4

Default Value

1

Data Type

Integer

Start Version

M_01-016-02-000

Variants Supported

Variant Supported
AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD PROFINET Yes
AKD Sercos® III Yes
AKD-N Yes
AKD-C No

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

EtherCAT CoE and CANopen
Index/Subindex Object Start Version

5420h/0

M_01-16-02-000
PROFINET and Sercos®
Fieldbus Address Attributes Signed?

PROFINET

3056 Byte No
Sercos® III 2 Octets
EtherNet/IP
Instance Data Size Data Type
1057 1 Byte Integer
Modbus
Register Address Is 64 bit? Attributes Signed? Object Start Version

2928

No 8 bit No M_01-16-02-000

Related Topics

Fault and Warning Messages