FAULT564.ACTION, FAULT565.ACTION

Description

These parameters set the action the AKD-C uses when the node count on string 1 (F564) or string 2 (F565) decreases. The supervision of nodes begins as soon as the nodes are powered (CPS.ACTIVE >= 3).

Value Action
0 Disable amplifier
1 Ignore
4 Generate warning

General Information

Type

R/W Parameter

Units

N/A

Range

0, 1, 4

Default Value

4

Data Type

Integer

Start Version

M_01-09-10-000

Variants Supported

Variant Supported
AKD Base No
AKD with Position Indexer No
AKD EtherCAT No
AKD CANopen No
AKD BASIC No
AKD SynqNet No
AKD EtherNet/IP No
AKD Profinet No
AKD sercos® III No
AKD-N No
AKD-C Yes

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see Supported Parameters (➜ p. 1).

Fieldbus

Address

Attributes Signed?

Profinet

2140

Byte No
sercos® III 2 Octets

Fieldbus

Index/Subindex

Is 64 bit? Attributes Signed?

Object Start Version

Modbus

280

No 8 bit No

M_01-03-00-000