100Ch Guard time


  • CAN bus only

The arithmetical product of the Objects 100Ch Guard Time and 100Dh Lifetime Factor is the response monitoring time. The Guard Time is given in milliseconds. The response monitoring is activated with the first Nodeguard object. If the value of the object Guard Time is set to zero, then the response monitoring is inactive.

Name Index Sub-Index Data Type Float Scale Units Access PDO Mappable
Guard time 100Ch 0h Unsigned16 - - Read/Write No