1704h RxPDO fixed mapping parameter 0x1704

Fixed map for supporting touch probe on axis 1.

Sub-Index Value Mapped Value
0 1 One PDO entry
1 0x60B80010 60B8h – Touch probe function

 

Name Index Sub-Index Data Type Float Scale Units Access PDO Mappable
Highest sub-index supported 1704h 0h Unsigned8 - - Read only No
Mapping entry 1 1704h 1h Unsigned32 - - Read only No