1720h RxPDO fixed mapping parameter 0x1720

Fixed map for supporting cyclic synchronous position mode on axis 2.

Sub-Index Value Mapped Value
0 2 Two PDO entries
1 0x68400010 6840h – Control Word
2 0x687A0020 687Ah – Target position

 

Name Index Sub-Index Data Type Float Scale Units Access PDO Mappable
Highest sub-index supported 1720h 0h Unsigned8 - - Read only No
Mapping entry 1 1720h 1h Unsigned32 - - Read only No
Mapping entry 2 1720h 2h Unsigned32 - - Read only No