1B25h TxPDO fixed mapping parameter 0x1b25

Fixed map for supporting touch probe 2 on axis 2.

Sub-Index Value Mapped Value
0 2 Two PDO entries
1 0x68BC0020 68BCh – Touch probe 2 position positive value
2 0x68BD0020 68BDh – Touch probe 2 position negative value

 

Name Index Sub-Index Data Type Float Scale Units Access PDO Mappable
Highest sub-index supported 1B25h 0h Unsigned8 - - Read only No
Mapping entry 1 1B25h 1h Unsigned32 - - Read only No
Mapping entry 2 1B25h 2h Unsigned32 - - Read only No