AXIS#.FAULT6004.ACTION

Description

This parameter determines the action the drive should take when F6004 occurs.

Parameter Value Drive Action
0 Disable Amplifier
1 Ignore (fault will not be reported)
2 Controlled Stop
3 Dynamic Brake
4 Generate Warning (See W6030)

Versions

Action Version Notes
Implemented 02-03-01-000

General Information

Type

Read/Write

Units

N/A

Range

0 to 4

Default Value

0

Data Type

Integer

Stored in Non-Volatile Memory

Yes

Variants Supported

All variants are supported.

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.FAULT6004.ACTION

501ch

01h

Unsigned8

-

-

Read/Write

No

AXIS2.FAULT6004.ACTION

511ch

01h

Unsigned8

-

-

Read/Write

No

EtherNet/IP

Name

ID

Hex

Data Type

Access

Units

AXIS1.FAULT6004.ACTION

7200

1C20

Unsigned8

Read/Write

-

AXIS2.FAULT6004.ACTION

72736

11C2

Unsigned8

Read/Write

-

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.FAULT6004.ACTION

7200

Unsigned8

Read/Write

-