AXIS#.FAULT6004.ACTION
Description
This parameter determines the action the drive should take when F6004 occurs.
Parameter Value | Drive Action |
---|---|
0 | Disable Amplifier |
1 | Ignore (fault will not be reported) |
2 | Controlled Stop |
3 | Dynamic Brake |
4 | Generate Warning (See W6030) |
Versions
Action | Version | Notes |
---|---|---|
Implemented | 02-03-01-000 |
General Information
Type |
Read/Write |
Units |
N/A |
Range |
0 to 4 |
Default Value |
0 |
Data Type |
Integer |
Stored in Non-Volatile Memory |
Yes |
Variants Supported
All variants are supported.
Fieldbus Information
Command |
Index |
SubIndex |
Data Type |
Units |
Float Scale |
Access |
PDO Mappable |
---|---|---|---|---|---|---|---|
AXIS1.FAULT6004.ACTION |
501ch |
01h |
Unsigned8 |
- |
- |
Read/Write |
No |
AXIS2.FAULT6004.ACTION |
511ch |
01h |
Unsigned8 |
- |
- |
Read/Write |
No |
Name |
ID |
Hex |
Data Type |
Access |
Units |
---|---|---|---|---|---|
AXIS1.FAULT6004.ACTION |
7200 |
1C20 |
Unsigned8 |
Read/Write |
- |
AXIS2.FAULT6004.ACTION |
72736 |
11C2 |
Unsigned8 |
Read/Write |
- |
Parameter |
PNU |
Data Type |
Access |
Units |
---|---|---|---|---|
AXIS#.FAULT6004.ACTION |
7200 |
Unsigned8 |
Read/Write |
- |