DRV.FAULT3008.ACTION
Description
This parameter determines the action the drive should take when F3008 occurs. See DRV.CPUPERCENT to monitor processor load.
Parameter Value | Drive Action |
---|---|
0 | Disable Amplifier |
1 | Ignore. Fault will not be reported. |
General Information
Type | Read/Write |
Units | N/A |
Range | 0 to 1 |
Default Value | 0 |
Data Type | Integer |
Stored in Non-Volatile Memory |
Yes |
Variants Supported
AKD2G
Fieldbus Information
Command |
Index |
SubIndex |
Data Type |
Units |
Float Scale |
Access |
PDO Mappable |
---|---|---|---|---|---|---|---|
DRV.FAULT3008.ACTION |
3000h |
0bh |
Unsigned8 |
- |
- |
Read/Write |
No |
Name |
ID |
Hex |
Data Type |
Access |
Units |
---|---|---|---|---|---|
DRV.FAULT3008.ACTION |
2023 |
7E7 |
Unsigned8 |
Read/Write |
- |
Parameter |
PNU |
Data Type |
Access |
Units |
---|---|---|---|---|
DRV.FAULT3008.ACTION |
2023 |
Unsigned8 |
Read/Write |
- |