AXIS#.SAFE.SS1_#.MODE

Description

Sets the behavior of the drive when the corresponding Safe Stop 1 (SS1) input is triggered.

Value Description

0

Drive Controlled - Drive performs a controlled stop following AXIS#.SAFE.SS1_#.DEC deceleration rate.

1

Fieldbus Controlled - The drive will not perform any stopping action, the fieldbus master should stop the drive within the configured AXIS#.SS1_#.TIMETOSTO amount of time before the drive triggers the STO signal. The manufacturer status object 50EFh, 51EFh Axis1 manufacturer status is used to signal to the fieldbus master that an SS1 input has been triggered.

Context

For complete SS1 information refer to see "SS1-t (Safe Stop 1)" / see "SS1-r (Safe Stop 1)".

Related safety parameters:

Versions

Action Version Notes

Implemented

02-01-00-000

General Information

Type

Read/Write

Units

N/A

Range

0 to 1

Default Value

0 (Drive Controlled)

Data Type

Integer

Stored in Non-Volatile Memory

Yes

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.SAFE.SS1_1.MODE

5007h

07h

Unsigned8

-

-

Read/Write

No

AXIS1.SAFE.SS1_2.MODE

5007h

08h

Unsigned8

-

-

Read/Write

No

AXIS1.SAFE.SS1_3.MODE

5007h

09h

Unsigned8

-

-

Read/Write

No

AXIS2.SAFE.SS1_1.MODE

5107h

07h

Unsigned8

-

-

Read/Write

No

AXIS2.SAFE.SS1_2.MODE

5107h

08h

Unsigned8

-

-

Read/Write

No

AXIS2.SAFE.SS1_3.MODE

5107h

09h

Unsigned8

-

-

Read/Write

No