Object 1018h: Identity Object (DS301)
The Identity Object contains general device information.
Index |
|
Name |
Identity Object |
Object code |
RECORD |
Data type |
Identity |
Category |
mandatory |
Subindex |
0 |
Description |
highest sub-index supported |
Data type |
UNSIGNED8 |
Category |
mandatory |
Access |
R/O |
PDO mapping |
not possible |
Value range |
1 to 4 |
Default value |
4 |
Subindex 1 is a unique number for a device manufacturer.
Subindex |
1 |
Description |
Vendor ID |
Category |
mandatory |
Access |
R/O |
PDO mapping |
not possible |
Value range |
UNSIGNED32 |
Default value |
0x6Ah (KollmorgenTG Drives) |
Subindex 2 contains four ASCII - characters, which determine the voltage range and current class of the device. The voltage range is one character L, M or H for low, medium and high voltage. The next three characters are showing the continuous current of the drive.
Subindex |
2 |
Description |
Product Code |
Category |
optional |
Access |
R/O |
PDO mapping |
not possible |
Value range |
e.g. M006 for an MV6 drive |
Default value |
no |
Subindex 3 consists of two revision numbers:
- The major revision number in the upper word containing the CAN-version.
- The minor revision number is not used in the AKD. The firmware version can be retrieved as a string via object 0x100A or as numbers voa object 0x2018 subindex 1 to 4.
E.g., a value of 0x0014 0000 means CAN-version 0.20.
Subindex |
3 |
Description |
Revision Number |
Category |
optional |
Access |
R/O |
PDO mapping |
not possible |
Value range |
UNSIGNED32 |
Default value |
no |
Subindex 4 gives the serial number of the drive. This number contains the following information in it:
- bits 0..14: Board serial number (production in week of year)
- bits 15..20: week of production
- bits 21..24: year of production - 2009
- bits 25..31: ASCII-code of MFR-ID
Subindex |
4 |
Description |
Serial Number |
Category |
optional |
Access |
R/O |
PDO mapping |
not possible |
Value range |
UNSIGNED32 |
Default value |
no |