DOUT21.STATEU to DOUT32.STATEU

Description

DOUTx.STATEU sets the state of the digital output node as follows:

0 = deactivated

1 = activated

DOUTx.STATEU is used when DOUTx.MODE = 0 (user mode).

General Information

Type

R/W Parameter

Units

N/A

Range

0 to 1

Default Value

0

Data Type

Integer

Start Version

M_01-01-01-000

Variants Supported

Supported by any AKD with extended IO.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

PROFINET and Sercos® III
Parameter Fieldbus Address Attributes Signed?
DOUT21.STATEU

PROFINET

2736 Byte No
Sercos® III 2 Octets
DOUT22.STATEU

PROFINET

2741 Byte
Sercos® III 2 Octets
DOUT23.STATEU

PROFINET

2746 Byte
Sercos® III 2 Octets
DOUT24.STATEU

PROFINET

2751 Byte
Sercos® III 2 Octets
DOUT25.STATEU

PROFINET

2756 Byte
Sercos® III 2 Octets
DOUT26.STATEU

PROFINET

2761 Byte
Sercos® III 2 Octets
DOUT27.STATEU

PROFINET

2766 Byte
Sercos® III 2 Octets
DOUT28.STATEU

PROFINET

2771 Byte
Sercos® III 2 Octets
DOUT29.STATEU

PROFINET

2776 Byte
Sercos® III 2 Octets
DOUT30.STATEU

PROFINET

2781 Byte
Sercos® III 2 Octets
Modbus
Parameter Register Address Is 64 bit? Attributes Signed?
DOUT21.STATEU 1472 No 8 bit No
DOUT22.STATEU 1482
DOUT23.STATEU 1492
DOUT24.STATEU 1502
DOUT25.STATEU 1512
DOUT26.STATEU 1522
DOUT27.STATEU 1532
DOUT28.STATEU 1542
DOUT29.STATEU 1552
DOUT30.STATEU 1562

Related Topics

Digital Outputs