FAULT314.ACTION
Description
The fault F314 is triggered if a motor phase loss condition is detected. The supervision of the motor lines is started if the following preconditions are met:
- Drive is enabled
- Current command is injected
The parameter FAULT314.ACTION can be configured to generate a fault F314, a warning n314 or to ignore the fault event. The configuration values are:
Value | Action |
---|---|
0 | Generate Fault |
1 | Ignore |
4 | Generate warning |
Restrictions: The motor phase loss condition cannot be detected if the motor is moving above a certain velocity level.
General Information
Type |
NV Parameter |
Units |
N/A |
Range |
0, 1, 4 |
Default Value |
1 |
Data Type |
Integer |
Start Version |
M_01-016-02-000 |
Variants Supported
Variant | Supported |
---|---|
AKD Base | Yes |
AKD with Position Indexer | Yes |
AKD EtherCAT | Yes |
AKD CANopen | Yes |
AKD BASIC | Yes |
AKD SynqNet | Yes* |
AKD EtherNet/IP | Yes |
AKD PROFINET | Yes |
AKD Sercos® III | Yes |
AKD-N | Yes |
AKD-C | No |
*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.
Fieldbus Information
If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type.
Index/Subindex | Object Start Version |
---|---|
5420h/0 |
M_01-16-02-000 |
Fieldbus | Address | Attributes | Signed? |
---|---|---|---|
PROFINET |
3056 | Byte | No |
Sercos® III | 2 Octets |
Instance | Data Size | Data Type |
---|---|---|
1057 | 1 Byte | Integer |
Register Address | Is 64 bit? | Attributes | Signed? | Object Start Version |
---|---|---|---|---|
2928 |
No | 8 bit | No | M_01-16-02-000 |