FB1.EXTENDEDMULTITURN

Description

This parameter allows additional multiturn information to be stored in non-volatile memory and restored on power up.

General Information

Type

R/W

Units

N/A

Range

0 to 1

Default Value

0

Data Type

Integer

Start Version

M_01-013-08-000

Variants Supported

Variant Supported
AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD PROFINET Yes
AKD Sercos® III Yes
AKD-N Yes
AKD-C No
AKD Base Yes

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

EtherCAT CoE and CANopen
Index/Subindex Object Start Version

535Eh /0

M_01-19-04-000
PROFINET and Sercos® III
Fieldbus Address Attributes Signed?

PROFINET

2862 Byte No
Sercos® III 2 Octets
EtherNet/IP
Instance Data Size Data Type
863 1 Byte None
Modbus
Register Address Is 64 bit? Attributes Signed? Object Start Version

1724

No 8 Bit No M_01-13-08-000

Related Topics

Extended Multiturn