AXIS#.IL.DI2T

Description

AXIS#.IL.DI2T is the output of the drive foldback algorithm in [%]. It is a representation of thermal load of the drive, also known as I2T, given in [%].

AXIS#.IL.DI2T=0% means the drive is at 0% thermal load and peak drive current can be applied. AXIS#.IL.DI2T=100% means the drive is at 100% thermal load and only continuous current can be applied.

Versions

Action Version Notes
Implemented 02-03-03-000

 

General Information

Type

Read Only

Units

%

Range

0 to 100%

Default Value

N/A

Data Type

Float

Stored in Non-Volatile Memory

No

Variants Supported

All variants are supported.

Industrial Ethernet Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.IL.DI2T

500ah

12h

Signed32

-

1000:1

Read only

No

AXIS2.IL.DI2T

510ah

12h

Signed32

-

1000:1

Read only

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

5825

1

5825 (0x16c1)

AXIS1.IL.DI2T

Signed32

Read Only

Yes

71361

2

5825 (0x16c1)

AXIS2.IL.DI2T

Signed32

Read Only

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.IL.DI2T

5825

Float

Read Only

-