AXIS#.SM.I1

Description

AXIS#.SM.I1 defines the current that is used in service motion modes 0 and 1 (see AXIS#.SM.MODE).

Versions

Action Version Notes
Implemented 02-00-00-000
     

General Information

Type

Read/Write

Units

Arms

Range

± Drive peak current (AXIS#.IPEAK )

Default Value

0.266 Arms

Data Type

Float

See Also

Service Motion, AXIS#.SM.I2

Stored in Non-Volatile Memory

Yes

Variants Supported

All variants are supported

Industrial Ethernet Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.SM.I1

500eh

01h

Signed32

-

1000:1

Read/Write

No

AXIS1.SM.I2

500eh

02h

Signed32

-

1000:1

Read/Write

No

AXIS2.SM.I1

510eh

01h

Signed32

-

1000:1

Read/Write

No

AXIS2.SM.I2

510eh

02h

Signed32

-

1000:1

Read/Write

No

EtherNet/IP

ID

Instance

Attribute

Name

Data Type

Access

User Mappable

6400

1

6400 (0x1900)

AXIS1.SM.I1

Signed32

Read/Write

Yes

71936

2

6400 (0x1900)

AXIS2.SM.I1

Signed32

Read/Write

Yes

6401

1

6401 (0x1901)

AXIS1.SM.I2

Signed32

Read/Write

Yes

71937

2

6401 (0x1901)

AXIS2.SM.I2

Signed32

Read/Write

Yes

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.SM.I1

6400

Float

Read/Write

-

AXIS#.SM.I2

6401

Float

Read/Write

-