CIP Sync Response Assembly Data Structure (106)

See Overview of the CIP Sync Assembly for more information.

Axis 1
Byte Index
Axis 2
Byte Index
Field Information
0 10 Status Word Status bits for the state machine and mode control   EIP.ASY106.AXIS#.STATUS
Bit (mask) Description Internal Behavior
0 (0x0001) Ready to Switch On See CIP Sync: State Machine
1 (0x0002) Switched On
2 (0x0004) Operation Enabled
3 (0x0008) Fault
4 (0x0010) Voltage Enabled
5 (0x0020) Quick Stop
6 (0x0040) Switch On Disabled
7 (0x0080) Warning
8 (0x0100) STO - Safe Torque Off See CIP Sync: State Machine
1 11 9 (0x0200) Remote
10 (0x0400) Target Reached
11 (0x0800) Internal Limit Active
12 (0x1000) Operation Mode Specific Bit 12 Home Attained
13 (0x2000) Operation Mode Specific Bit 13 1) Homing Error 2) Position Following Error
14 (0x4000) Manufacturer Specific Bit 14 Motion Mode Selected (0 = Homing, 1 = Cyclic Position)
15 (0x8000) Manufacturer Specific Bit 15 Following Position
2 - 5 12 - 15 Position Command input to virtual axis in PLC The axis' server loop position command scaled into fieldbus position units EIP.ASY106.AXIS#.P
6 - 9 16 - 19 Position Actual The axis' servo loop position feedback scaled into fieldbus position units EIP.ASY106.AXIS#.PFB
Additional Bytes Index  
20 - 23 Reserved
24 - 63 Dynamic Mapping Space