CAP#.STATE
Description
Reports if the capture channel has captured a value. When the first value is captured, this will change to one and stay at one. This is reset to zero when the capture is armed.
If capture is configured to auto-rearm, CAP#.REARM is 1, then this will be set to one on the first trigger but will not change on subsequent triggers. In this case, you may want to use CAP#.COUNT to detect when each new value has been captured.
Examples
Usage
0: Not Captured
1: Captured
Code
-->CAP1.STATE 0 -->
Context
For more information please refer to Capture.
Versions
Action | Version | Notes |
---|---|---|
Implemented | 02-00-00-000 |
General Information
Type |
Read Only |
Units |
N/A |
Range |
0 to 1 |
Default Value |
0 |
Data Type |
Integer |
Stored in Non-Volatile Memory |
No |
Variants Supported
All variants are supported.
Fieldbus Information
Name |
ID |
Hex |
Data Type |
Access |
Units |
---|---|---|---|---|---|
CAP1.STATE |
31090 |
7972 |
Unsigned8 |
Read Only |
- |
CAP2.STATE |
31091 |
7973 |
Unsigned8 |
Read Only |
- |
Parameter |
PNU |
Data Type |
Access |
Units |
---|---|---|---|---|
CAP1.STATE |
31090 |
Unsigned8 |
Read Only |
- |
CAP2.STATE |
31091 |
Unsigned8 |
Read Only |
- |