MODBUS.ERRORMODE

Description

Enables or disables error response messages. When a Modbus read or write request is received there are certain operations where the drive can ignore an internal error. The following internal errors can be ignored.

  • Reading or writing to a Modbus address that is not mapped.
  • Writing to a Modbus address that is mapped to a parameter that is read-only.
  • The mapped parameter returns an error.

If MODBUS.ERRORMODE is set to ignore errors and an error is read, it returns zero and all writes are ignored. The AKD2G drive always returns an error code even if the Modbus request is badly formed.

Errors are always logged regardless of MODBUS.ERRORMODE. MODBUS.ERRORS can be used to see additional information about the error.

Value

Description

0

Send error response messages.

1

Do not send error response messages (default).

Context

For more information, see Modbus Errors.

Versions

Action Version Notes

Implemented

02-05-00-000

 

General Information

Type

Read Write Parameter

Units

N/A

Range

0 to 1

Default Value

1

Data Type

Integer

See Also

MODBUS.CLRERRORS
MODBUS.ERRORCOUNT
MODBUS.ERRORS

Stored in Non-Volatile Memory

Yes

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

MODBUS.ERRORMODE

3014h

03h

Unsigned8

-

-

Read/Write

No

EtherNet/IP

Name

ID

Hex

Data Type

Access

Units

MODBUS.ERRORMODE

3705

E79

Unsigned8

Read/Write

-

PROFINET

Parameter

PNU

Data Type

Access

Units

MODBUS.ERRORMODE

3705

Unsigned8

Read/Write

-