AXIS#.HOME.MOVE

Description

AXIS#.HOME.MOVE starts a homing move. AXIS#.OPMODE must be set to 2 (position mode) and AXIS#.CMDSOURCE must be set to 0 (Service).

AXIS#.STOP can be used to stop homing after it has started.


  • When a Gantry is configured (GANTRY.STATE > 0) issuing AXIS1.HOME.MOVE will start homing on both axes (1 and 2). To ensure the gantry moves together, AXIS1.HOME.V, HOME.ACC and HOME.DEC will be used on both Axis 1 and Axis 2.

  • When both axes have successfully completed, the Gantry State will increase to 2, indicating the Gantry is now active.

Versions

Action Version Notes
Implemented 02-00-00-000

General Information

This content is not applicable to KAS.

Type

Command

Units

N/A

Range

N/A

Default Value

N/A

Data Type

N/A

See Also

AXIS#.HOME.MODE

Stored in Non Volatile Memory

No

Variants Supported

All variants are supported.

Related Topics

Homing