DRV.DISSOURCES is a bitwise parameter that returns the status of possible causes of a drive disable. If this parameter is 0, then the drive is enabled.
The return value specific bits are as follows:
Bit |
Status and Response |
Drive Action |
---|---|---|
0 |
Software disable (execute DRV.EN to issue software enable) |
Performs action configured by DRV.DISMODE. |
1 |
Fault exists (read DRV.FAULTS to get the active faults) |
Device disables using the defined reaction for the detected fault. |
2 |
Hardware disable (remote enable input is low) |
Power stage disabled. |
3 |
In-rush disable (the in-rush relay is opened) |
Performs action configured by DRV.DISMODE. |
4 |
Initialization disable (the drive did not finish the initialization process) |
Power stage disabled. |
5 |
Controlled stop disable from a digital input. |
Controlled stop. |
The states indicated by this keyword, can be viewed by clicking the "Axis active/Axis inactive" button at the bottom of WorkBench: