FAULT314.ACTION

Description

The fault F314 is triggered if a motor phase loss condition is detected. The supervision of the motor lines is started if the following preconditions are met:

  • Drive is enabled
  • Current command is injected

The parameter FAULT314.ACTION can be configured to generate a fault F314, a warning n314 or to ignore the fault event. The configuration values are:

Value Action
0 Generate Fault
1 Ignore
4 Generate warning

Restrictions: The motor phase loss condition cannot be detected if the motor is moving above a certain velocity level.

General Information

Type

NV Parameter

Units

N/A

Range

0, 1, 4

Default Value

1

Data Type

Integer

Start Version

M_01-016-02-000

FieldbusClosedA Fieldbus is an industrial network system for real-time distributed control (e.g. CAN or Profibus). It is a way of connecting instruments in a plant design

Index/Subindex

Object Start Version

EtherCATClosedEtherCAT is an open, high-performance Ethernet-based fieldbus system. The development goal of EtherCAT was to apply Ethernet to automation applications which require short data update times (also called cycle times) with low communication jitter (for synchronization purposes) and low hardware costs COE and CANopen

5420h/0

M_01-16-02-000

Related Topics

Fault and Warning Messages