500Eh, 510Eh AXIS#.SM.*

The following tables specify the CANopen mapping for the axis specific service motion objects.

Axis 1

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable
Highest sub-index supported 500Eh 0h Unsigned8 - - Read only No
AXIS1.SM.I1 500Eh 1h Signed32 1000:1 - Read/Write No
AXIS1.SM.I2 500Eh 2h Signed32 1000:1 - Read/Write No
AXIS1.SM.MODE 500Eh 3h Unsigned16 - - Read/Write No
AXIS1.SM.T1 500Eh 4h Unsigned16 - - Read/Write No
AXIS1.SM.T2 500Eh 5h Unsigned16 - - Read/Write No
AXIS1.SM.V1 500Eh 6h Signed32 - Velocity Read/Write No
AXIS1.SM.V2 500Eh 7h Signed32 - Velocity Read/Write No

Axis 2

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable
Highest sub-index supported 510Eh 0h Unsigned8 - - Read only No
AXIS2.SM.I1 510Eh 1h Signed32 1000:1 - Read/Write No
AXIS2.SM.I2 510Eh 2h Signed32 1000:1 - Read/Write No
AXIS2.SM.MODE 510Eh 3h Unsigned16 - - Read/Write No
AXIS2.SM.T1 510Eh 4h Unsigned16 - - Read/Write No
AXIS2.SM.T2 510Eh 5h Unsigned16 - - Read/Write No
AXIS2.SM.V1 510Eh 6h Signed32 - Velocity Read/Write No
AXIS2.SM.V2 510Eh 7h Signed32 - Velocity Read/Write No