605Ah, 685Ah Quick stop option code - Axis #
The object controls how the drive responds to the quick stop bit in the controlword (6040h).
Value |
|
1 |
Perform a stop using profile deceleration ramp (6084h) and transition into Switch On Disabled state, axis will disable. |
2 |
Perform a stop using AXIS#.CS.DEC deceleration ramp and transition into Switch On Disabled state, axis will disable (Default). |
5 |
Perform a stop using profile deceleration ramp (6084h) and stay in Quick Stop Active, axis will stay enabled. |
6 |
Perform a stop using AXIS#.CS.DEC deceleration ramp and stay in Quick Stop Active, axis will stay enabled. |
Axis 1
Parameter |
Index |
Sub-Index |
Data Type |
Float Scale |
Units |
Access |
PDO Mappable |
Quick stop option code - Axis 1 |
605Ah |
0h |
Signed16 |
- |
- |
Read/Write |
No |
Axis 2
Parameter |
Index |
Sub-Index |
Data Type |
Float Scale |
Units |
Access |
PDO Mappable |
Quick stop option code - Axis 2 |
685Ah |
0h |
Signed16 |
- |
- |
Read/Write |
No |