| 3110h |
F2015 |
Bus over voltage . |
| 3120h |
F2000 |
Vbus read is out of thresholds. |
| 3130h |
F2008 |
Bus capacitor overloaded. |
| 3180h |
W2008 |
Bus capacitor overloaded. |
| 3181h |
F2014 |
AC input phase loss. |
| 3182h |
F2016 |
Gate supply under voltage. |
| 3183h |
W1000 |
Fan stalled. |
| 3190h |
F1005 |
Unrecognized FPGA fault. |
| 3191h |
F1006 |
FPGA cyclic read fault. |
| 3210h |
F2006 |
Bus over voltage. |
| 3220h |
F2007 |
Bus under voltage. |
| 3280h |
W2007 |
Bus under voltage. |
| 3281h |
W2010 |
Regen energy critical. |
| 3282h |
F2013 |
Regen short circuit. |
| 3283h |
W2006 |
Bus over voltage. |
| 4210h |
F2500 |
Control over temperature . |
| 4310h |
F2501 |
Power over temperature sensor. |
| 4382h |
F1001 |
Power board type mismatch detected. |
| 4390h |
W2500 |
Control Over Temp . |
| 4391h |
W2501 |
Power Over Temp Sensor. |
| 4394h |
W2502 |
Control Under Temp Sensor. |
| 4395h |
W2503 |
Power Under Temp Sensor. |
| 4398h |
F2502 |
Control under temperature sensor. |
| 4399h |
F2503 |
Power under temperature sensor. |
| 5580h |
F1100 |
NV Memory Data (might occur when downloading firmware). |
| 5588h |
F1101 |
Flash directory error. |
| 5590h |
F1102 |
Identity read failed. |
| 5591h |
F1103 |
Invalid MAC Address. |
| 55A1h |
F1104 |
Power board factory settings file read failed. |
| 55A2h |
F1105 |
Power board updateable settings file read failed. |
| 55B0h |
F1106 |
Failure reading Control Board FPGA EDS file. |
| 55B1h |
F1107 |
Power Board Resident FPGA not valid. |
| 55B2h |
F1108 |
Power Board Operational FPGA not valid. |
| 55B3h |
F1109 |
Failure reading Power Board FPGA EDS. |
| 55C4h |
F1002 |
Power Board Communication fault. |
| 55C5h |
F1003 |
Power Board FPGA not configured. |
| 6080h |
F3000 |
Issued command timed out. |
| 6380h |
F5005 |
Drive motor parameters setup incomplete. |
| 6381h |
F3001 |
Failed to default parameters. |
| 7180h |
F5000 |
Motor overheated. |
| 7184h |
F5003 |
Brake applied when it should be released. |
| 7186h |
W5000 |
Motor Temperature high. |
| 7187h |
F2011 |
Voltage exceeds motors rating. |
| 7188h |
F2009 |
Regen near capacity, could not prevent over voltage. |
| 7189h |
F5004 |
Brake released when it should be applied. |
| 718Ah |
F2018 |
Broken Wire Connection to Motor. |
| 7190h |
F5001 |
Brake 1 current out of range. |
| 7191h |
W5001 |
Brake override active. |
| 7192h |
F5002 |
Brake 2 current out of range. |
| 7193h |
F5006 |
Temperature sensor detected open circuit. |
| 7194h |
W5007 |
Brake override active but no brake configured. |
| 7380h |
F4100 |
Feedback: Parity fault. |
| 7381h |
F4101 |
Feedback: Overrun fault. |
| 7382h |
F4102 |
Feedback: Framing fault. |
| 7383h |
F4103 |
Feedback: fault. |
| 7384h |
F4104 |
Feedback: Communication Timeout fault. |
| 7385h |
F4105 |
Feedback: Initialization sequence fault. |
| 7386h |
F4106 |
Feedback: Temperature fault. |
| 7387h |
F4107 |
Feedback: Battery fault. |
| 7388h |
F4108 |
Feedback: Sensor fault. |
| 7389h |
F4109 |
Feedback: Device-unique fault 0. |
| 738Ah |
F4110 |
Feedback: Device-unique fault 1. |
| 738Bh |
F4111 |
Feedback: Analog Signal fault. |
| 738Ch |
F4112 |
Feedback: Broken Wire fault. |
| 738Dh |
F4113 |
Feedback: Power Supply fault. |
| 738Eh |
F4114 |
Feedback: Illegal Hall state (111, 000). |
| 738Fh |
F4115 |
Failed to set feedback type. |
| 7392h |
F4116 |
Failed to read motor parameters from . |
| 7393h |
F4117 |
SFA communication fault. |
| 7394h |
F4118 |
SFA over current. |
| 7395h |
F4119 |
SFA under voltage. |
| 7396h |
F4120 |
Feedback: Safety fault. |
| 7397h |
F3004 |
Operation in Position Mode with Halls Only feedback not allowed. |
| 7398h |
F4121 |
Feedback: Watchdog fault. |
| 7399h |
F4122 |
Unrecognized feedback fault. |
| 739Ah |
F4123 |
SFA Resident FPGA not valid. |
| 739Bh |
F4124 |
SFA Operational FPGA not valid. |
| 739Ch |
F4125 |
SFA FPGA file read failed. |
| 739Dh |
F4126 |
SFA Factory file read failed. |
| 739Eh |
W4100 |
Feedback parity. |
| 739Fh |
W4101 |
Feedback overrun. |
| 73A0h |
W4102 |
Feedback framing. |
| 73A1h |
W4103 |
Feedback CRC. |
| 73A2h |
W4104 |
Feedback communication timeout. |
| 73A3h |
W4105 |
Feedback initialization sequence. |
| 73A4h |
W4106 |
Feedback temperature. |
| 73A5h |
W4107 |
Feedback battery. |
| 73A6h |
W4108 |
Feedback sensor. |
| 73A7h |
W4109 |
Feedback device-unique warning 0. |
| 73A8h |
W4110 |
Feedback device-unique warning 1. |
| 73A9h |
W4111 |
Gearing feedback source fault. |
| 73C0h |
F5500 |
Wake and Shake - Insufficient movement |
| 73C1h |
F5501 |
Wake and Shake - Excess movement |
| 73C2h |
F5502 |
Wake and Shake - Fine-Coarse delta too large. |
| 73C3h |
F5503 |
Wake and Shake - Over speed |
| 73C4h |
F5504 |
Wake and Shake - Loop angle delta too large. |
| 73C5h |
F5505 |
Wake and Shake - Commutation not initialized. |
| 73C6h |
F5506 |
Wake and Shake - Motor U phase missing. |
| 73C7h |
F5507 |
Wake and Shake - Motor V phase missing. |
| 73C8h |
F5508 |
Wake and Shake - Motor W phase missing. |
| 73C9h |
W5500 |
Wake & Shake configured or active. |
| 73D0h |
F5509 |
Wake and Shake - Validating Positive Movement Failed. |
| 73D1h |
F5510 |
Wake and Shake - Validating Negative Movement Failed. |
| 73D2h |
F5511 |
Wake and Shake - Validating Comm. angle timed out. |
| 73D3h |
F5512 |
Wake and Shake - Validating Comm. angle moved too far - Bad Comm Angle. |
| 73D4h |
F5513 |
Wake and Shake - Validating Comm. angle required more than MOTOR.ICONT |
| 73D5h |
F6002 |
Invalid commutation detected - motor accelerating in the wrong direction.
Motor phase may be incorrect. |
| 8130h |
F7002 |
Heartbeat lost. |
| 8180h |
W7000 |
Fieldbus Error Passive. |
| 8311h |
F2017 |
Motor Foldback. |
| 8331h |
F2001 |
Drive Foldback. |
| 8380h |
W2001 |
Drive foldback imminent! Reduce Load. |
| 8381h |
W2002 |
Motor foldback imminent! Reduce Load. |
| 8382h |
W2003 |
Motor I2t load! Reduce load. |
| 8383h |
W6008 |
Using derivative of position when using sensorless feedback type in
position mode |
| 8384h |
W6004 |
Zero velocity when using induction sensorless feedback type in
mode. |
| 8385h |
W6027 |
Current Command Saturated. |
| 8386h |
F5514 |
Wake and Shake - Limit Switch Hit |
| 8480h |
F6000 |
Over speed. |
| 8481h |
F6005 |
Emergency timeout occurred. |
| 8582h |
W6006 |
Positive Limit Switch triggered. |
| 8583h |
W6007 |
Negative Limit Switch triggered. |
| 8611h |
F6001 |
Following error magnitude fault. |
| 8685h |
F6003 |
Instability during autotune. |
| 8688h |
W6000 |
Velocity Limit Violation, Exceeding Max Limit. |
| 8689h |
W6009 |
Following Motion Failed; Check Motion Parameters . |
| 868Ah |
W6010 |
Target Position crossed due to Stop command. |
| 86A0h |
W6011 |
Index pulse not found. |
| 86A1h |
W6012 |
Home switch not found. |
| 86A3h |
W6014 |
Motion Task Activation Failed. |
| 86A4h |
W6015 |
Homing Failed. |
| 86A5h |
F6004 |
Target position was overshot due to invalid motion task activation. |
| 86A8h |
W6017 |
Motion task target position is out of modulo-range. |
| 86A9h |
W6018 |
Motion task target position is out of software-limits. |
| 86AAh |
W6019 |
Invalid bit-combination in the motion-task control-word. |
| 86ABh |
W6020 |
1:1 profile can not be triggered on-the-fly. |
| 86ACh |
W6021 |
Customer profile table is not initialized. |
| 86ADh |
W6022 |
Motion task activation is currently pending. |
| 86AEh |
W6002 |
Homing is needed. |
| 86AFh |
W6023 |
Homing maximum distance exceeded. |
| 8780h |
F7001 |
Fieldbus Sync frames lost. |
| 8781h |
W7001 |
PLL unlocked. |
| 8782h |
F7003 |
PLL failed to acquire lock. |
| 8783h |
F7004 |
PLL lost lock. |
| 8784h |
F7005 |
Fieldbus cyclic setpoints missing. |
| 8785h |
F7006 |
Only on CAN drives: CAN hardware initialization failed. |
| 8AF0h |
W6025 |
Homing and feedback mismatch. |
| FF00h |
W2011 |
No Power on IO 24V Rail. |
| FF01h |
F7000 |
Fieldbus Communication lost. |
| FF02h |
F2004 |
Iu current offset limit exceeded. |
| FF03h |
F2005 |
Iv current offset limit exceeded. |
| FF04h |
F2010 |
Regen over power. |
| FF05h |
F3100 |
MechaWare Model failed to connect Analog Input, fix model. |
| FF06h |
F3101 |
MechaWare Model failed to connect Analog Output, fix model. |
| FF07h |
F2002 |
Output over current. |
| FF08h |
F2003 |
Current sensor short circuit. |
| FF09h |
F3002 |
Assert check failed. |
| FF0Ah |
F2012 |
Power stage fault. |
| FF0Bh |
F9000 |
Safe torque off. |
| FF0Ch |
W9000 |
Safe torque off. |
| FF0Dh |
F1000 |
Firmware and FPGA versions are not compatible. |
| FF0Eh |
W6001 |
Exceeding following error magnitude warning level. |
| FF0Fh |
F3003 |
External Fault. |
| FF10h |
W6003 |
OPMODE incompatible with CMDSOURCE. |
| FF11h |
F1004 |
Failed to initialize the system. |
| FF12h |
F5100 |
.FBSOURCE has unidentified feedback selected. |
| FF13h |
F5101 |
VL.FBSOURCE has unidentified feedback selected. |
| FF14h |
F5102 |
PL.FBSOURCE has unidentified feedback selected. |
| FF15h |
F1007 |
A Factory MechaWare model failed to load. |
| FF16h |
F1008 |
A User MechaWare model failed to load. |
| FF17h |
W6028 |
Gear feedback source is invalid. |
| FF18h |
F6028 |
Gearing feedback source is invalid. |
| FF19h |
F6006 |
Current home mode requires HOME.IPEAK to be set. |
| FF1Ah |
W6026 |
Current homing mode requires HOME.IPEAK to be set by user |
| FF50h |
F9002 |
SMM Communication Failed. |
| FF51h |
F9003 |
Incorrect safety card detected. |
| FF52h |
F9004 |
Safe torque off pulse and standard lines don't match. |
| FF53h |
F9005 |
Simultaneity Fault: Safe torque off lines don't match each other. |
| FF54h |
W9011 |
SMM I/O failure detected |
| FF55h |
F9006 |
SMM in failed state. |
| FF56h |
W9008 |
Brake Test Time Overflow. |
| FF57h |
W9009 |
SMM Over Temperature. |
| FF58h |
W9010 |
SMM State Not Operational. |
| FF59h |
W9007 |
Safe brake parameters inconsistent |
| FF5Ah |
F9007 |
Safe brake parameters inconsistent. |