FB1.INITPSTATUS
Description
This parameter reports the status of the initial position comparison:
| Value | Description |
|---|---|
| 0 | Initial position check is in progress. |
| 1 | Initial position check is disabled. |
| 2 | Position difference between power-up and power-down is less than value of FB1.INITPWINDOW at start up. |
| 3 | Position difference between power-up and power-down is greater than or equal to value of FB1.INITPWINDOW at start up. |
| 4 | Initial position check encountered an error condition. |
General Information
|
Type |
R/O Parameter |
|
Units |
N/A |
|
Range |
N/A |
|
Default Value |
N/A |
|
Data Type |
Integer |
|
Start Version |
M_01-10-00-000 |
Related Topics
Initial Position Check | FB1.INITPSAVED | FB1.INITPWINDOW