FB1.PDIR
Description
FB1.PDIR will change the sign and with it the direction of feedback channel 1.
Example
If position feedback = 35,185.932 counts and you set:
--> FB1.PDIR 1
then position feedback = -35,185.932 counts
General Information
|
Type |
NV-Parameter |
|
Units |
None |
|
Range |
0 to 1 |
|
Default Value |
0 |
|
Data Type |
U8 |
|
See Also |
N/A |
|
Start Version |
M_01-05-11-000 |