AXIS#.MOTOR.CTF0

Description

This parameter is used to configure the thermal constant of the motor coil, which is the break frequency of a single-pole low-pass filter model of the thermal dynamics of the motor coil.

This parameter, together with AXIS#.MOTOR.IPEAK and AXIS#.MOTOR.ICONT , determine the motor foldback (thermal protection) operating values.

Calculating AXIS#.MOTOR.CTF0

Given a motor coil/winding thermal time constant T in seconds, then:

AXIS#.MOTOR.CTF0 = 1/(2πT)


  • This parameter is automatically configured for Kollmorgen motors when MOTOR.AUTOSET=1.

Context

For more information see Motor.

Versions

Action Version Notes
Implemented 02-00-00-000

General Information

Type

Read/Write

Units

mHz

Range

0.265 to 16,000

Default Value

10

Data Type

Float

See Also

N/A

Stored in Non Volatile Memory

Yes

Variants Supported

All variants are supported.

Fieldbus Information

FieldbusClosedA Fieldbus is an industrial network system for real-time distributed control (e.g. CAN or Profibus). It is a way of connecting instruments in a plant design Parameter Index Sub-Index Data Type Float Scale Units Access PDOClosedPDO is a type of protocol frame used in some fieldbuses. A PDO contains one or more object dictionary entries, which define the application data transferred between devices. Mappable
EtherCATClosed***EtherCAT is an open, high-performance Ethernet-based fieldbus system. The development goal of EtherCAT was to apply Ethernet to automation applications which require short data update times (also called cycle times) with low communication jitter (for synchronization purposes) and low hardware costs COE and CANopen AXIS1.MOTOR.CTF0 0x500B 0xE UDINT 1000:1 - RW False
AXIS2.MOTOR.CTF0 0x510B 0xE UDINT 1000:1 - RW False