AXIS#.MOTOR.PHSADVK2
Description
This parameter is used for IPM motors (AXIS#.MOTOR.TYPE = 6). AXIS#.MOTOR.PHSADVK2 is the second order polynomial coefficient used to determine the direct axis current command for commutation phase advance, according to the equation:
IdCmd(Ip) = PHSADVK2 * Ip^2 + PHSADVK1 * Ip
where Ip is the magnitude of the motor phase current:
Ip = sqrt(Id^2 + Iq^2)
-
-
This parameter is automatically configured for Kollmorgen motors when MOTOR.AUTOSET=1 and motor memory version is 0.3 or greater.
-
-
This parameter is required to be configured for AXIS#.MOTOR.TYPE = 6.
Context
For more information see Motor.
Versions
Action | Version | Notes |
---|---|---|
Implemented | 02-00-00-000 |
General Information
Type |
Read/Write |
Units |
N/A |
Range |
-1.0 to 1.0 |
Default Value |
0 |
Data Type |
Float |
Stored in Non Volatile Memory |
Yes |
Variants Supported
All variants are supported.