FB1.IDENTIFIED
Description
This parameter is set according to FB1.SELECT on drive power up if FB1.SELECT is not –1; otherwise the parameter value is read from the drive memory.
Type |
Description |
---|---|
0 |
Unknown |
1 | No encoder |
10 |
Incremental encoder with A/B Quad, marker pulse and Hall |
11 |
Incremental encoder with A/B Quad, marker pulse and no Hall |
12 | Halls Only |
20 |
Sine Encoder , with marker pulse and Hall |
21 |
Sine encoder , with marker pulse & No Halls |
30 |
EnDat 2.1 with Sine Cosine |
31 |
EnDat 2.2 |
32 |
|
33 |
HIPERFACE |
34 |
BiSS Mode C Renishaw |
40 |
Resolver |
41 |
|
42 | Tamagawa. This feedback type is not available on models with extension type NA (AKD Models). |
43 | Network Cyclic Feedback |
44 | FB2 Cyclic Feedback |
45 | SFD3 |
46 | Hiperface DSL |
50 | Reserved |
63 | Simulated Motor |
General Information
Type |
R/O Parameter |
Units |
N/A |
Range |
N/A |
Default Value |
N/A |
Data Type |
Integer |
See Also |
FB1.SELECT |
Start Version |
M_01-00-00-000 |