Drive States
|
State |
StatusWord |
||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
15 |
14 |
13 |
12 |
11 |
0 |
9 |
8 |
7 |
6 |
5 |
4 |
3 |
2 |
1 |
0 |
||||
|
Not Ready to Switch On |
X |
X |
X |
X |
X |
X |
X |
X |
X |
0 |
X |
X |
0 |
0 |
0 |
0 |
|||
|
Switch On Disabled |
X |
X |
X |
X |
X |
X |
X |
X |
X |
1 |
X |
X |
0 |
0 |
0 |
0 |
|||
|
Ready to Switch On |
X |
X |
X |
X |
X |
X |
X |
X |
X |
0 |
1 |
X |
0 |
0 |
0 |
1 |
|||
|
Switched On |
X |
X |
X |
X |
X |
X |
X |
X |
X |
0 |
1 |
X |
0 |
0 |
1 |
1 |
|||
|
Operation Enable |
X |
X |
X |
X |
X |
X |
X |
X |
X |
0 |
1 |
X |
0 |
1 |
1 |
1 |
|||
|
Quick Stop Active |
X |
X |
X |
X |
X |
X |
X |
X |
X |
0 |
0 |
X |
0 |
1 |
1 |
1 |
|||
|
Fault Reaction Active |
X |
X |
X |
X |
X |
X |
X |
X |
X |
0 |
X |
X |
1 |
1 |
1 |
1 |
|||
|
Fault |
X |
X |
X |
X |
X |
X |
X |
X |
X |
0 |
X |
X |
1 |
0 |
0 |
0 |
|||
Not Ready to Switch On:
-
Drive is being initialized
-
Drive function is disabled (no energy is supplied to the motor)
-
Drive is not ready to accept commands
Switch On Disabled:
-
Drive initialization is complete
-
Drive parameters have been set up
-
Drive parameters may be changed
-
Drive function is disabled (no energy is supplied to the motor)
Ready To Switch On:
-
Drive parameters may be changed
-
Drive function is disabled (no energy is supplied to the motor)
Switched On:
-
Power amplifier is ready
-
Drive parameters may be changed
-
Drive function is disabled (no energy is supplied to the motor)
Operation Enable:
-
No faults have been detected
-
Drive function is enabled, and power is applied to the motor
-
Drive parameters may be changed
Quick Stop Active:
-
Drive parameters may be changed
-
Quick stop function is being executed
-
Drive function is enabled, and power is applied to the motor
Fault Reaction Active (*) :
-
Drive parameters may be changed
-
A fault has occurred in the drive
-
Drive function is enabled, and power is applied to the motor
Fault (*):
-
Drive parameters may be changed
-
A fault has occurred in the drive
-
Drive function is disabled (no energy is supplied to the motor)
Note:
(*) Drive faults may be fatal or non-fatal. When a fatal fault occurs, the drive device is no longer able to control the motor, so an immediate switch-off of the motor is necessary.