Drive States

State

StatusWord

15

14

13

12

11

0

9

8

7

6

5

4

3

2

1

0

Not Ready to Switch On

X

X

X

X

X

X

X

X

X

0

X

X

0

0

0

0

Switch On Disabled

X

X

X

X

X

X

X

X

X

1

X

X

0

0

0

0

Ready to Switch On

X

X

X

X

X

X

X

X

X

0

1

X

0

0

0

1

Switched On

X

X

X

X

X

X

X

X

X

0

1

X

0

0

1

1

Operation Enable

X

X

X

X

X

X

X

X

X

0

1

X

0

1

1

1

Quick Stop Active

X

X

X

X

X

X

X

X

X

0

0

X

0

1

1

1

Fault Reaction Active

X

X

X

X

X

X

X

X

X

0

X

X

1

1

1

1

Fault

X

X

X

X

X

X

X

X

X

0

X

X

1

0

0

0

Not Ready to Switch On:

  • Drive is being initialized

  • Drive function is disabled (no energy is supplied to the motor)

  • Drive is not ready to accept commands

Switch On Disabled:

  • Drive initialization is complete

  • Drive parameters have been set up

  • Drive parameters may be changed

  • Drive function is disabled (no energy is supplied to the motor)

Ready To Switch On:

  • Drive parameters may be changed

  • Drive function is disabled (no energy is supplied to the motor)

Switched On:

  • Power amplifier is ready

  • Drive parameters may be changed

  • Drive function is disabled (no energy is supplied to the motor)

Operation Enable:

  • No faults have been detected

  • Drive function is enabled, and power is applied to the motor

  • Drive parameters may be changed

Quick Stop Active:

  • Drive parameters may be changed

  • Quick stop function is being executed

  • Drive function is enabled, and power is applied to the motor

Fault Reaction Active (*) :

  • Drive parameters may be changed

  • A fault has occurred in the drive

  • Drive function is enabled, and power is applied to the motor

Fault (*):

  • Drive parameters may be changed

  • A fault has occurred in the drive

  • Drive function is disabled (no energy is supplied to the motor)

Note:

(*) Drive faults may be fatal or non-fatal. When a fatal fault occurs, the drive device is no longer able to control the motor, so an immediate switch-off of the motor is necessary.