I2T_Current_Limit

Index.Sub 2908.0H
Data Type Unsigned16
Access Read Only
PDO Mappable No
Unit  0.1A2 · sec

Range

0 to 65535
Default Value --
Store Supported Yes
Description

This value is used for I2T Protection functionality and returns the I2T current limit value:

                2908.0H = [ ( 290C.0H)- (2005.4H)2 ] · 2902.0H

Objects used in the formula above:

 I2T_Current_Limit 2908.0H
I2T_Peak_Current 290C.0H
Nominal_Current 2005.4H
I2T_TMax_Peak_Current 2902.0H

Notes

This object is not available in EtherCAT fieldbus.

See I2T Motor Overload Protection.