FB1.BISSBITS

Description

FB1.BISSBITS specifies the number of BiSS sensor (position) bits for the BiSS Mode C encoder in use. Typically the value is either 26 or 32 for a BiSS Mode C Renishaw encoder. The required value for this parameter is provided by the feedback device manufacturer for the particular device being used.

General Information

Type

NV Parameter

Units

bits

Range

0 to 64 bits

Default Value

32 bits

Data Type

Integer

See Also

FB1.SELECT, FB1.IDENTIFIED

Start Version

M_01-01-00-100 and M_01-01-03-000

Variants Supported

Variant Supported
AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD PROFINET Yes
AKD Sercos® III Yes
AKD-N Yes
AKD-C No

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

EtherCAT CoE and CANopen
Index/Subindex Object Start Version

508Ch /0

M_01-00-00-000
PROFINET and Sercos® III
Fieldbus Address Attributes Signed?

PROFINET

2140 Byte No
Sercos® III 2 Octets
EtherNet/IP
Instance Data Size Data Type
141 1 Byte Integer
Modbus
Register Address Is 64 bit? Attributes Signed? Object Start Version

280

No 8 bit No M_01-03-00-000

Related Topics

Feedback 1