FB1.POFFSET

Description

FB1.POFFSET is the value added to the primary feedback position (FB1.P).

Example

If FB1.P is 10000 counts and FB1.POFFSET is set to –10000 counts, then the next read of FB1.P will return ~0 counts.

General Information

Type

NV-Parameter

Units

counts, custom units

Range

-5,123,372,000,000,005.000 to 5,123,372,000,000,005.000 counts

or

-10,485,760.000 to 10,485,760.000 custom units

Default Value

0

Data Type

S64

See Also

N/A

Start Version

M_01-05-11-000

Variants Supported

Variant Supported
AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD PROFINET Yes
AKD Sercos® III Yes
AKD-N Yes
AKD-C No

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

EtherCAT CoE and CANopen
Index/Subindex Object Start Version
3490h/0 M_01-00-00-000
PROFINET and Sercos® III
Fieldbus Address Attributes Signed?

PROFINET

2809 DWord Yes
Sercos® III 8 Octets
EtherNet/IP
Instance Data Size Data Type
810 8 Byte Signed Position
Modbus
Register Address Is 64 bit? Attributes Signed? Object Start Version

1618

Yes 64-bits Yes M_01-06-03-000