FB2.SOURCE
Description
This parameter sets the secondary feedback source to be either the EEO connector (X9) or the high speed opto inputs on the I/O Connector (X7) as follows:
0 = None
1 = Feedback Source X9 (EEO connector)
2 = Feedback Source X7 (High Speed Opto Inputs on the I/O Connector)
FB2 5V Power Supply Notes:
If FB2.SOURCE = 0 or 2 (X7), the 5V power supply will remain off.
If FB2.SOURCE = 1 (X9) the FB2 5V power supply will remain on unless a short is detected. This is useful for encoder types that may require calibration.
General Information
Type |
R/W Parameter |
Units |
N/A |
Range |
0 to 2 |
Default Value |
0 |
Data Type |
Integer |
See Also |
FB2.ENCRES, FB2.MODE, PL.FBSOURCE |
Start Version |
M_01-03-00-000 |
Variants Supported
Variant | Supported |
---|---|
AKD Base | Yes |
AKD with Position Indexer | Yes |
AKD EtherCAT | Yes |
AKD CANopen | Yes |
AKD BASIC | Yes |
AKD SynqNet | Yes* |
AKD EtherNet/IP | Yes |
AKD PROFINET | Yes |
AKD Sercos® III | Yes |
AKD-N | No |
AKD-C | No |
*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.
Fieldbus Information
If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type.
Index/Subindex | Object Start Version |
---|---|
51EEh /0 |
M_01-03-00-000 |
Fieldbus | Address | Attributes | Signed? |
---|---|---|---|
PROFINET |
2494 | Word | No |
Sercos® III | 2 Octets |
Instance | Data Size | Data Type |
---|---|---|
495 | 2 Byte | Integer |
Register Address | Is 64 bit? | Attributes | Signed? |
---|---|---|---|
988 |
No | 16 bit | No |