MOTOR.PHSADVK1
Description
This parameter is supported for IPM motors (MOTOR.TYPE = 6). MOTOR.PHSADVK1 is the first order polynomial coefficient used to determine the direct axis current command for commutation phase advance, according to the equation:
IdCmd(Ip) = PHSADVK2 * Ip^2 + PHSADVK1 * Ip
where Ip is the magnitude of the motor phase current:
Ip = sqrt(Id^2 + Iq^2)
-
- This parameter is automatically configured for Kollmorgen motors when AXIS#.MOTOR.AUTOSET = 1 and can be modified while AXIS#.MOTOR.AUTOSET = 1 if its AXIS#.MOTOR.DISAUTOSET index = 1.
General Information
Type |
NV Parameter |
Units |
N/A |
Range |
-1.0 to 1.0 |
Default Value |
0 |
Data Type |
Float |
Start Version |
M_01-11-00-000 |
Variants Supported
Variant | Supported |
---|---|
AKD Base | Yes |
AKD with Position Indexer | Yes |
AKD EtherCAT | Yes |
AKD CANopen | Yes |
AKD BASIC | Yes |
AKD SynqNet | Yes* |
AKD EtherNet/IP | Yes |
AKD PROFINET | Yes |
AKD Sercos® III | Yes |
AKD-N | Yes |
AKD-C | No |
*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.
Fieldbus Information
If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type.
Fieldbus | Address | Attributes | Signed? |
---|---|---|---|
PROFINET |
2895 | DWord | Yes |
Sercos® III | 4 Octets |
Instance | Data Size | Data Type |
---|---|---|
896 | 4 Byte Signed | Float |
Register Address | Is 64 bit? | Attributes | Signed? | Object Start Version |
---|---|---|---|---|
1790 |
No | 32 bit | Yes | M_01-03-00-000 |