AXIS#.SAFE.SS2_#.MODE

Description

Sets the behavior of the drive when the corresponding Safe Stop 2 (SS2) input is triggered.

Value Description

0

Drive Controlled - Drive performs a controlled stop following AXISx.SAFE.SS2_x.DEC deceleration rate.

1

Fieldbus Controlled - The drive will not perform any stopping action. The fieldbus master should stop the drive within the configured AXISx.SAFEPARAM.SS2_x.TIMETOSOS amount of time before the drive triggers the configured fault reaction. The manufacturer status object 667Fh, 6E7Fh SS2 statuses is used to signalize to the fieldbus master that an SS2 input has been triggered.

Context

For complete SS2 information refer to (see "SS2 (Safe Stop 2)").

Related safety parameters:

Versions

Action Version Notes

Implemented

02-04-00-000

Implemented in SMM revision v0.56

General Information

Type

Read/Write

Units

N/A

Range

0 to 1

Default Value

Drive controlled

Data Type

Integer

Stored in Non-Volatile Memory

Yes

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.SAFE.SS2_1.MODE

5007h

0dh

Unsigned8

-

-

Read/Write

No

AXIS1.SAFE.SS2_2.MODE

5007h

0eh

Unsigned8

-

-

Read/Write

No

AXIS2.SAFE.SS2_1.MODE

5107h

0dh

Unsigned8

-

-

Read/Write

No

AXIS2.SAFE.SS2_2.MODE

5107h

0eh

Unsigned8

-

-

Read/Write

No