FB1.INITSIGNED

Description

This parameter sets whether the initial value of the feedback read from the feedback device will be set as a signed or as an unsigned value.

0 = Unsigned

1 = Signed

The drive internal process for the feedback initialization is as follows:

  1. Reads the position feedback.
  2. Adds the origin to the feedback.
  3. Determines modulo from Step 2 by the actual feedback bits.
  4. Sets the position feedback sign according to FB1.INITSIGNED.

General Information

Type

NV Parameter

Units

N/A

Range

0 to 1

Default Value

1

Data Type

Integer

See Also

FB1.ORIGIN

Start Version

M_01-00-00-000

Variants Supported

Variant Supported
AKD Base Yes
AKD with Position Indexer Yes
AKD EtherCAT Yes
AKD CANopen Yes
AKD BASIC Yes
AKD SynqNet Yes*
AKD EtherNet/IP Yes
AKD Profinet Yes
AKD sercos® III Yes
AKD-N Yes
AKD-C No

*In SynqNet, a parameter may be available in the firmware but have no effect on the system. See SynqNet Supported Parameters.

Fieldbus Information

If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type. For information on SynqNet parameters see SynqNet Supported Parameters.

Fieldbus

Index/Subindex

Object Start Version

EtherCAT COE and CANopen

508Fh /0

M_01-00-00-000

Fieldbus

Address

Attributes Signed?

Profinet

2143

Byte Yes
sercos® III 2 Octets
Fieldbus Instance Data Size Data Type
EtherNet/IP 144 1 Byte Signed Integer

Fieldbus

Index/Subindex

Is 64 bit? Attributes Signed?

Object Start Version

Modbus

286

No 8 bit Yes

M_01-03-00-000

Related Topics

Feedback 1