60B9h, 68B9h Touch probe status - AxisX

The status of the two touch probes associated with an axis. The EtherCAT or CANopen master can use this value to check if 60Bah to 60BDh contain values. If a touch probe is disabled, bit 0, then the latched bits, bits 1 and 2, are always 0.

See Touch Probes.

Bit

Value Touch Probe Description
0 0 1 Touch probe is disabled
1 Touch probe is enabled
1 0

Touch probe 1 no positive edge value stored

1 Touch probe 1 positive edge position stored
2 0

Touch probe 1 no negative edge value stored

1 Touch probe 1 negative edge position stored
3 to 7 - Reserved
8 0 2 Touch probe 2 is disabled
1 Touch probe 2 is enabled
9 0 Touch probe 2 no positive edge value stored
1 Touch probe 2 positive edge position stored
10 0

Touch probe 2 no negative edge value stored

1 Touch probe 2 negative edge position stored
11 to 15 -

Reserved

Axis 1

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable SMM Versions
Touch probe status - Axis 1 60B9h 0 Unsigned16 - - Read only Yes All

Axis 2

Parameter Index Sub-Index Data Type Float Scale Units Access PDO Mappable SMM Versions
Touch probe status - Axis 2 68B9h 0 Unsigned16 - - Read only Yes All