MOTOR.CTF0

General Information

Type

NV Parameter

Description

Sets the thermal constant of the motor coil.

Units

mHz

Range

0.265 to 16,000 mHz

Default Value

10 mHz

Data Type

Float

See Also

N/A

Start Version

M_01-00-00-000

Description

This parameter is used to configure the thermal constant of the motor coil, which is the break frequency of a single-pole low-pass filter model of the thermal dynamics of the motor coil.

This parameter, together with MOTOR.IPEAK and MOTOR.ICONT , determine the motor foldback parameters IL"Instruction list" This is a low-level language and resembles assembly.MFOLDD,IL.MFOLDT, and IL.MFOLDR.

Calculating MOTOR.CTF0

Given a motor coil/winding thermal time constant T in seconds, then:

MOTOR.CTF0 = 1/(2πT)