SWLS.LIMIT1

General Information

Type

NV Parameter

Description

Sets the position of the software travel limit switch 0.

Units

Position units

Range

-9,007,199,254,740,992 to 9,007,199,254,740,991

Default Value

1,048,576.000 counts, 16-bit (firmware versions M_01-02-00-000 and above)

68,719,476,736 counts (for firmware version M_01-01-00-000)

Data Type

S64

Start Version

M_01-00-00-000

FieldbusA Fieldbus is an industrial network system for real-time distributed control (e.g. CAN or Profibus). It is a way of connecting instruments in a plant design

Index/Subindex

Object Start Version

EtherCATEtherCAT is an open, high-performance Ethernet-based fieldbus system. The development goal of EtherCAT was to apply Ethernet to automation applications which require short data update times (also called cycle times) with low communication jitter (for synchronization purposes) and low hardware costs COE and CANopen

607Dh/2

M_01-00-00-000

Description

This parameter sets the compare register for the software limit switch 1. This value can be either the lower or the upper software limit switch register, depending on the configuration of the software limit switches:

These switches can be used in addition to hardware limit switches. The software limit switches are only active if the axis is homed. For more information about homing, please refer to the HOME Parameters and DRV.MOTIONSTAT.

Related Topics

Limits

 