IL.MI2TFTHRESH

Description

This parameter defines a fault threshold for ILClosed "Instruction list" This is a low-level language and resembles assembly.MI2T. A fault F309 will be generated as soon as IL.MI2T is higher than the value of IL.MI2TFTHRESH. This can only happen with IL.MIMODE set to 1.

General Information

Type

NV Parameter

Units

%

Range

0% to 100%

Default Value

0%

Data Type

Integer

Start Version

M_01-18-01-000

Variants Supported

FieldbusClosed A Fieldbus is an industrial network system for real-time distributed control (e.g. CAN or Profibus). It is a way of connecting instruments in a plant design

Index/Subindex

Object Start Version

EtherCATClosed ***EtherCAT is an open, high-performance Ethernet-based fieldbus system. The development goal of EtherCAT was to apply Ethernet to automation applications which require short data update times (also called cycle times) with low communication jitter (for synchronization purposes) and low hardware costs COE and CANopen

5469h/0