Axis Settings

The Settings view allows you to configure the axis command source, operation mode, and axis direction. This section can be reached by first selecting an Axis under your device, and then selecting Settings in the lower navigation pane.

By default, only settings applicable to your current axis operation mode and command source will appear in the navigation tree. To show all settings available for the device (even if the these settings are not used with the current operation mode and command source), right click on Settings and select Show all Settings.

Settings View

From the main Settings view, you can configure the following drive settings:

Element Description Parameter

Command Source

Selects where the command is being provided: 
  1. Service: For tuning and commanding motion via theAKD2G setup screens
  2. Fieldbus: For normal KAS Runtime operation
AXIS#.CMDSOURCE

Operation Mode

Selects the servo loops that are used in the drive.
  1. Current Loop (used primarily during drive setup)
  2. Velocity and Current Loops (used primarily during drive setup)
  3. Position, Velocity, and Current Loops (Default KAS Runtime mode)
AXIS#.OPMODE

Axis Direction

Sets the direction of the motor. The drive must be disengaged to change this.
  1. Standard Direction of Motion
  2. Reversed Direction of Motion
AXIS#.DIR