F4x09 Detailed Troubleshooting Steps

Description

Fault 4x09 is a feedback specific fault. Fault 4x09 has different causes depending on the feedback attached

 

Troubleshooting Steps

Feedback Cause

Remedy

Hiperface DSL Triggered when the position estimator is enabled for ~300uS. The position estimator becomes enabled when the drive loses communication with the feedback device.

Evaluate cables, connections, and any potential noise sources.1

SFD

Configuration checksum fault. Communication issue or incorrectly programmed encoder.

Re-initialize feedback. If the problem persists, contact Customer Support.

EnDat

Error indicated by encoder.

Evaluate cables, connections, and any potential noise sources.1

1 See Wiring and EMI Noise Reduction for instructions on wiring and recommendations for EMI noise reduction.

Versions

Action Version Notes
Implemented 02-00-00-000  

General Information

Type

Feedback

Reaction

Disable axis

Clearable

Yes*

* When attempting to clear the fault, the feedback is powered down and back up and re-initialized. If communication is successful, the fault will clear.

Variants Supported

Supported on all device types.

Related Topics