SCA (Safe Cam)

SCA description for drive option Functional Safety 3.

Description

SCA is a pure monitoring function which has no fault reaction. Once configured, it stays activated monitoring whether the position stays within a position window. The parameter n_UL_SCA defines the upper limit and the parameter n_LL_SCA defines the lower limit of this window.

The SCA function returns a logical status, called InRange, which tells whether the position is currently located in the position window or not.

Number of Instances

Three instances per axis.

Function Input / Output Variables

 

 

Input

  • Safe position: position signal from safe feedback

Outputs

  • SCA InRange: logical status telling if the position is in the range defined by the SCA function

Activation

No activation source. Once configured in the safety parameters, it stays activated.

Related Parameters

Safety parameters

Name

Variables

Default

Parameter

Function Activation

-

0 (Never active)

AXIS#.SAFEPARAM.SCA_#​.FUNCTIONACTIVATION

Position Upper Limit

s_UL_SCA

0 (Pos user units)

AXIS#.SAFEPARAM.SCA_#​.POSUPPERLIMIT

Position Lower Limit

s_LL_SCA

0 (Pos user units)

AXIS#.SAFEPARAM.SCA_#​.POSLOWERLIMIT

Diagnostic parameters

Name

Variables

Default

Parameter

SCA In Range

-

-

AXIS#.SAFE.SCA_#.INRANGE

Function Internal Status

-

-

AXIS#.SAFE.SCA_#.INTERNALSTATE

Timing

Setup in WorkBench

Select the drive and open the Safety Parameterization view (see "Parameters Editor").

Choose the axis (1), category (2), SCA function (3) and the instance number (4).

Safety State / Status Signals

The signal AXIS#.SAFE.SCA_#.INRANGE can be monitored by safe digital outputs with OSSD pulses (see "OSSD"). The status signal must be mapped to the safe digital output. Two outputs can be combined to a dual channel output. For parameter description refer to Functional Safety Parameter Reference.

Safety Properties

Refer to (➜ # 1, Safety Properties Overview).