MOTOR.CTF0
Description
This parameter is used to configure the thermal constant of the motor coil, which is the break frequency of a single-pole low-pass filter model of the thermal dynamics of the motor coil.
This parameter, together with MOTOR.IPEAK and MOTOR.ICONT , determine the motor foldback parameters IL.MFOLDD ,IL.MFOLDT , and IL.MFOLDR .
Calculating MOTOR.CTF0
Given a motor coil/winding thermal time constant T in seconds, then:
MOTOR.CTF0 = 1/(2πT)
-
- This parameter is automatically configured for Kollmorgen motors when MOTOR.AUTOSET=1.
General Information
Type |
NV Parameter |
Units |
mHz |
Range |
0.265 to 16,000 mHz |
Default Value |
10 mHz |
Data Type |
Float |
See Also |
N/A |
Start Version |
M_01-00-00-000 |
Index/Subindex |
Object Start Version |
|
---|---|---|
3454h/0 |
M_01-00-00-000 |